Refresqueria Rico Summer

7551 Bissonnet St, Houston, TX 77074
Mexican / Latin
Last inspected: Aug 13, 2025
70
Score
Medium Risk

Refresqueria Rico Summer, located at 7551 Bissonnet St in Houston, TX, underwent a moderate risk inspection on August 13, 2025. The inspection identified seven minor violations. These violations included issues with hot storage temperature measurement devices, improper plumbing fixture installation, and inadequate provision of drain boards or utensil racks.

1
Inspections
0
Critical latest
0
Major latest
7
Minor latest
Inspection History
Aug 13, 2025
Routine
7 minor violations.
70
Violations — Aug 13, 2025 Inspection
Hot storage. food temperature measuring device not available to check internal food temperatures of hot time/temperature controlled for safety (tcs) food for equipment not bearing thermometers.
20-21.03(c)(01)
Plumbing fixture installation. plumbing fixtures, including compartment type utensil-and-food sinks, hand-washing sinks and mop or utility sinks, not installed to preclude splashes from running down mounting surfaces behind and adjacent to the fixture. acceptable installation methods include a liquid tight seal between fixture and mounting surface, insertion into a precut counter, table or cabinet with a perimeter seal or any other effective method. all materials used shall be safe, smooth, impervious and easily cleanable.
20-21.10(m)
Drain boards, utensil racks or easily movable dish tables of adequate size not provided for proper handling of soiled utensils prior to washing and for cleaned utensils following sanitizing / not located so as not to interfere with the proper use of the dishwashing facilities.
20-21.12(b)
Using chemicals for sanitization. when using chemicals for sanitization, a test kit or other device that accurately measures the concentration of the solution in parts per million or milligrams per liter not provided and used.
20-21.12(g)
Backflow. an air gap between the water supply inlet and the flood level rim of the plumbing fixture / equipment / or nonfood equipment not at least twice the diameter of the water supply inlet and may not be less than 25 mm (1 inch). a backflow or backsiphonage prevention device installed on a water supply system shall meet american society of sanitary engineering (asse) standards for construction, installation, maintenance, inspection, and testing for that specific application and type of device. a backflow prevention device shall be located so that it can be serviced and maintained. a hose shall not be attached to a faucet unless a backflow prevention device is installed.
20-21.17(c)
Utility line installation. utility service lines and pipes unnecessarily exposed on floors in those areas listed in section 20-21.23(b) of this code.
20-21.22(g)
Floor junctures. when allowed in this subsection, the juncture between walls and floors presenting an open seam of more than one-thirty-second of an inch.
20-21.22(f)
Substantial (Critical)
Serious (Major)