Love Croissants Corporation
Last inspected: Dec 30, 2025
82
Score
Love Croissants Corporation, located at 3038 Antoine Dr, Houston, TX, underwent a low-risk inspection on December 30, 2025. The inspection identified four minor violations related to plumbing fixture installation, materials used for equipment, and backflow prevention. Historical data indicates a pattern of low-risk inspections across three scored events for this Houston establishment.
3
Inspections
0
Critical latest
0
Major latest
4
Minor latest
Inspection History
Dec 30, 2025
Routine
4 minor violations.
82
Dec 23, 2024
Routine
9 minor violations. 3 corrected on site.
64
Dec 2, 2024
Routine
21 minor violations. 4 corrected on site.
35
Violations — Dec 30, 2025 Inspection
Plumbing fixture installation. plumbing fixtures, including compartment type utensil-and-food sinks, hand-washing sinks and mop or utility sinks, not installed to preclude splashes from running down mounting surfaces behind and adjacent to the fixture. acceptable installation methods include a liquid tight seal between fixture and mounting surface, insertion into a precut counter, table or cabinet with a perimeter seal or any other effective method. all materials used shall be safe, smooth, impervious and easily cleanable.
20-21.10(m)
Materials; general. multi-use equipment and utensils not designed, constructed and repaired with safe materials, including finishing materials / not corrosion-resistant and nonabsorbent / not smooth, easily cleanable and durable under conditions of normal use.
20-21.10(a)
Backflow. an air gap between the water supply inlet and the flood level rim of the plumbing fixture / equipment / or nonfood equipment not at least twice the diameter of the water supply inlet and may not be less than 25 mm (1 inch). a backflow or backsiphonage prevention device installed on a water supply system shall meet american society of sanitary engineering (asse) standards for construction, installation, maintenance, inspection, and testing for that specific application and type of device. a backflow prevention device shall be located so that it can be serviced and maintained. a hose shall not be attached to a faucet unless a backflow prevention device is installed.
20-21.17(c)
Toilet room. toilet room not provided with tight-fitting / self-closing / solid doors, which shall be closed except during cleaning or maintenance except that this requirement does not apply to a toilet room that is located outside a food establishment and does not open directly into the food establishment such as a toilet room that is provided by the management of a shopping mall or stadium-type facilities.
20-21.18(c)
Substantial (Critical)
Serious (Major)
General (Minor)