Fuel Express #14
Last inspected: Nov 20, 2024
70
Score
Fuel Express #14, located at 211 W Crosstimbers in Houston, TX, underwent its most recent inspection on November 20, 2024. This inspection resulted in a moderate risk score of 70, with seven minor violations noted. The violations included the use of shipping containers for storage, improper installation of plumbing fixtures to prevent splashing, and issues with backflow prevention devices.
1
Inspections
0
Critical latest
0
Major latest
7
Minor latest
Inspection History
Nov 20, 2024
Routine
7 minor violations.
70
Violations — Nov 20, 2024 Inspection
General. using shipping containers / milk / produce crates as storage racks / support shelves.
20-21.03(a)(02)c
Plumbing fixture installation. plumbing fixtures, including compartment type utensil-and-food sinks, hand-washing sinks and mop or utility sinks, not installed to preclude splashes from running down mounting surfaces behind and adjacent to the fixture. acceptable installation methods include a liquid tight seal between fixture and mounting surface, insertion into a precut counter, table or cabinet with a perimeter seal or any other effective method. all materials used shall be safe, smooth, impervious and easily cleanable.
20-21.10(m)
Backflow. an air gap between the water supply inlet and the flood level rim of the plumbing fixture / equipment / or nonfood equipment not at least twice the diameter of the water supply inlet and may not be less than 25 mm (1 inch). a backflow or backsiphonage prevention device installed on a water supply system shall meet american society of sanitary engineering (asse) standards for construction, installation, maintenance, inspection, and testing for that specific application and type of device. a backflow prevention device shall be located so that it can be serviced and maintained. a hose shall not be attached to a faucet unless a backflow prevention device is installed.
20-21.17(c)
Openings. outside openings not protected against the entrance of insects by filling or closing holes and other gaps along floors / walls / ceilings / tight-fitting, self-closing doors, kept closed / closed windows / screening / properly designed and installed air curtains to control flying insects / other means.
20-21.21(b)
Construction. walls, including nonsupporting partitions / wall coverings / ceilings, of walk-in refrigerating units / food preparation areas / food storage areas / food display areas / equipment-washing areas / utensil-washing areas not light-colored / smooth / nonabsorbent / easily cleanable except for ceilings over areas used only for beverage preparation and/or service. concrete or pumice blocks used for interior wall construction in these locations shall be finished and sealed to provide an easily cleanable surface except in dry storage areas.
20-21.23(b)
Maintenance. walls / ceilings, including doors, windows, skylights, and similar closures, not maintained in good repair.
20-21.23(a)
Attachments. light fixtures / vent covers / wall-mounted fans / similar equipment not including decorative items attached to walls and ceilings not easily cleanable / not maintained in good repair / not kept clean.
20-21.23(g)
Substantial (Critical)
Serious (Major)
General (Minor)
Nearby Restaurants