Buddy's #10
Last inspected: Nov 4, 2024
95
Score
Buddy's #10, located at 8003 Howard Drive in Houston, Texas, underwent a low-risk inspection on November 4, 2024. The inspection report noted one minor violation concerning backflow prevention. This violation detailed requirements for air gaps, ASSE standards for backflow devices, and hose attachments.
1
Inspections
0
Critical latest
0
Major latest
1
Minor latest
Inspection History
Nov 4, 2024
Routine
1 minor violation.
95
Violations — Nov 4, 2024 Inspection
Backflow. an air gap between the water supply inlet and the flood level rim of the plumbing fixture / equipment / or nonfood equipment not at least twice the diameter of the water supply inlet and may not be less than 25 mm (1 inch). a backflow or backsiphonage prevention device installed on a water supply system shall meet american society of sanitary engineering (asse) standards for construction, installation, maintenance, inspection, and testing for that specific application and type of device. a backflow prevention device shall be located so that it can be serviced and maintained. a hose shall not be attached to a faucet unless a backflow prevention device is installed.
20-21.17(c)
Substantial (Critical)
Serious (Major)
General (Minor)