Long John Silvers
Last inspected: Dec 23, 2025
67
Score
LONG JOHN SILVERS, located at 1906 W Bell Rd in Phoenix, AZ, underwent a food establishment inspection on December 23, 2025. This inspection resulted in a moderate risk score of 67, with one critical, two major, and one minor violation noted. The violations observed pertained to handwashing sinks, manual warewashing requirements, and the provision and maintenance of a three-compartment sink.
1
Inspections
1
Critical latest
2
Major latest
1
Minor latest
Inspection History
Dec 23, 2025
Routine
1 critical violation. 2 major violations. 1 minor violation. 1 corrected on site.
67
Violations — Dec 23, 2025 Inspection
Insufficient number of handwashing sinks
Inspector notes: No handwash station in the warewashing area AND front service area --- provide handwash station in warewashing area and front service area, all handwash stations are to be within 25 ft from point of service, clearly visible with no physical barriers Hot water dispenser installed at handwash station area. -- relocated hot water dispenser, handwash area limited to handwashing area Correct By: Correct Prior To Reinspection
5-203.11
Warewashing sink compartments insufficient or improperly set up
(corrected on site)
Inspector notes: Three compartment sink setup with wash and sanitizer compartment. Middle compartment has food debris in the bottom of the sink. Employee pre-rinsing dishes in the middle compartment --- employee cleaned sink, educated three compartment sink is to be washed, rinsed and sanitize; if facility needs to prerinse prior then sink not be setup and then cleaned/setup
4-301.12(A-B)
Plumbing system not maintained in good repair
Inspector notes: No mixing faucet for the mopsink faucet -- provide Three compartment sink plumbed directly to the sewer. --- provide riser for the three compartment sink that is below the bottom of the three compartment sink basin height No food prep sink -- Provide food prep sink Ice machine plumbing not connected and leaks on the floor -- provide 1 inch air gap to the floor drain, preferably hub floor drain No backflow preventer for the soda system, hot water dispenser and tea machine --- provide ASSE 1013 reduced pressure zone backflow preventer for the soda system, no copper/brass downstream and test certification required at time of reinspection provide ASSE 1022 dual check valve for the tea machine and the hot water dispenser
5-205.15(A)
Floors, walls, or ceilings not easily cleanable
Inspector notes: Missing cleanout covers, holes in the walls, damaged FRP at the mopsink area and at the cook line behind the ovens, damaged cove base at the mopsink, wood shelf above mopsink in disrepair -- repair with semi-gloss paint or replace with approved surface, cook line handwash station has an inch of caulk between wall and sink (not attached) and screws not stainless steel and rusting, front cabinets in disrepair and laminate, acoustic ceiling tiles in the front service area, missing outlet covers, flooring in walk in cooler freezer and threshold in disrepair, not sealed, gaps in the hood, unsealed wood in the cabinets -- all surfaces are to be easy cleanable, durable, non-absorbent and smooth, laminate surfaces not an approved finish since not durable, provide vinyl white ceiling tiles, provide cleanout covers, provide frp that is sealed in good repair, seal all cracks, crevices and pentrations, provide flooring in the walk in cooler that is in good repair and sealed/flush
6-201.11
Priority (Critical)
Priority Foundation (Major)